EF, BF, FF Supported-Side Support Units: 22 Models for 6-40 mm Shafts
EF, BF and FF are supported-side support units. They carry radial load and support the screw end without locating it axially; the fixed-side unit on the other end controls axial position. This table covers 22 catalogue models for 6-40 mm shafts.
EF supported-side square units
EF uses a square housing and a single bearing with a stop ring. The model code follows the bearing size rather than the shaft diameter in several rows, so read d from the table instead of decoding the model name.
| Model | d (mm) | L | B | H | b | h1 | B1 | H1 | P | d1 | d2 | h | Bearing | Stop ring | Mass (kg) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| EF 6 | 6 | 12 | 42 | 25 | 21 | 13 | 18 | 20 | 30 | 5.5 | 9.5 | 11 | 606ZZ | C6 | 0.07 |
| EF 8 | 6 | 14 | 52 | 32 | 26 | 17 | 25 | 26 | 38 | 6.6 | 11 | 12 | 606ZZ | C6 | 0.13 |
| EF 10 | 8 | 20 | 70 | 43 | 35 | 25 | 36 | 24 | 52 | 9 | — | — | 608ZZ | C8 | 0.33 |
| EF 12 | 10 | 20 | 70 | 43 | 35 | 25 | 36 | 24 | 52 | 9 | — | — | 6000ZZ | C10 | 0.32 |
| EF 15 | 15 | 20 | 80 | 49 | 40 | 30 | 41 | 25 | 60 | 9 | — | — | 6002ZZ | C15 | 0.38 |
| EF 20 | 20 | 26 | 95 | 58 | 47.5 | 30 | 56 | 25 | 75 | 11 | — | — | 6204ZZ | C20 | 0.63 |
BF supported-side square units
BF covers 8-40 mm shafts with a square housing. It uses a different bearing series from EF and adds a C1/C2 cover stack. Check the housing height and bolt pattern against the machine base.
| Model | d (mm) | L | B | H | b | h1 | B1 | H1 | P | d1 | d2 | h | Bearing | Stop ring | Mass (kg) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| BF 10 | 8 | 20 | 60 | 39 | 30 | 22 | 34 | 32.5 | 46 | 6.6 | 10.8 | 5 | 608ZZ | C8 | 0.29 |
| BF 12 | 10 | 20 | 60 | 43 | 30 | 25 | 35 | 32.5 | 46 | 6.6 | 10.8 | 1.5 | 6000ZZ | C10 | 0.3 |
| BF 15 | 15 | 20 | 70 | 48 | 35 | 28 | 40 | 38 | 54 | 6.6 | 11 | 6.5 | 6002ZZ | C15 | 0.38 |
| BF 17 | 17 | 23 | 86 | 64 | 43 | 39 | 50 | 55 | 68 | 9 | 14 | 8.5 | 6203ZZ | C17 | 0.74 |
| BF 20 | 20 | 26 | 88 | 60 | 44 | 34 | 52 | 50 | 70 | 9 | 14 | 8.5 | 6004ZZ | C20 | 0.76 |
| BF 25 | 25 | 30 | 106 | 80 | 53 | 48 | 64 | 70 | 85 | 11 | 17.5 | 11 | 6205ZZ | C25 | 1.42 |
| BF 30 | 30 | 32 | 128 | 89 | 64 | 51 | 76 | 78 | 102 | 14 | 20 | 13 | 6206ZZ | C30 | 1.97 |
| BF 35 | 35 | 32 | 140 | 96 | 70 | 52 | 88 | 79 | 114 | 14 | 20 | 13 | 6207ZZ | C35 | 2.22 |
| BF 40 | 40 | 37 | 160 | 110 | 80 | 60 | 100 | 90 | 130 | 18 | 26 | 17.5 | 6208ZZ | C40 | 3.27 |
FF supported-side round units
FF covers 6-30 mm shafts in a round flange. It is the round-flange counterpart to BF and uses a stop ring instead of a locknut. The PCD and flange diameter decide whether it fits an existing mounting hole.
| Model | d (mm) | L | H | F | D | A | PCD | B | d1 | d2 | h | Bearing | Stop ring | Mass (kg) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| FF 6 | 6 | 10 | 6 | 4 | 22 | 36 | 28 | 28 | 3.4 | 6.5 | 4 | 606ZZ | C6 | 0.04 |
| FF 10 | 8 | 12 | 7 | 5 | 28 | 43 | 35 | 35 | 3.4 | 6.5 | 4 | 608ZZ | C8 | 0.07 |
| FF 12 | 10 | 15 | 7 | 8 | 34 | 52 | 42 | 42 | 4.5 | 8 | 4 | 6000ZZ | C10 | 0.11 |
| FF 15 | 15 | 17 | 9 | 8 | 40 | 63 | 50 | 52 | 5.5 | 9.5 | 5.5 | 6002ZZ | C15 | 0.2 |
| FF 20 | 20 | 20 | 11 | 9 | 57 | 85 | 70 | 68 | 6.6 | 11 | 6.5 | 6204ZZ | C20 | 0.27 |
| FF 25 | 25 | 24 | 14 | 10 | 63 | 98 | 80 | 79 | 9 | 14 | 8.5 | 6205ZZ | C25 | 0.67 |
| FF 30 | 30 | 27 | 18 | 9 | 75 | 117 | 95 | 93 | 11 | 17.5 | 11 | 6206ZZ | C30 | 1.07 |
Checks before an equivalent quote
- Confirm the complete support unit code and whether it is fixed-side or supported-side. The two sides use different bearing arrangements and cannot be swapped by flange size alone.
- Match shaft journal diameter, tolerance and thread. A unit with the right outside flange can still have the wrong bore or locknut thread.
- Check the mounting surface height H and pilot or counterbore dimensions against the machine base. A few tenths of a millimetre change the screw centre height.
- Confirm bearing class, contact angle and preload. The catalogue bearing code in the table is a starting point, not a guarantee of the existing build.
- Check the locknut, spacer and cover stack. Mixed parts from another supplier can change the axial position of the screw.
- For a replacement, send the housing drawing, shaft end drawing and the measured distance from the mounting face to the screw centre.
Supported-side FAQ
Does a supported-side unit take thrust?
No. It is designed mainly for radial support. The fixed-side unit on the other end should take the axial load and locate the screw. Check the machine drawing before changing the bearing arrangement.
Why is the EF model number different from the shaft diameter?
Some EF model codes follow the bearing size, not the shaft diameter. Use the d column in the table and confirm the shaft journal drawing; do not infer the bore from the model prefix alone.
Can BF and FF be exchanged?
Only when the flange shape, PCD, bore, height and bearing series match. BF is square and FF is round; the mounting hole pattern is different even when the shaft diameter is the same.
Related knowledge
- Fixed-side support units category
- Ball screw model index
- Support units and accessories
- Supported-side units: EF, BF, FF
- MC nut brackets and RN lock nuts
- Seals, QZ lubricators and covers
- Ball screw product range
- Accuracy and preload
- Installation checks
- Lubrication and relubrication
- Send a model and drawing
- Knowledge index
Cross-reference source: SC15 ball screw catalogue (513C), pages 324-329, checked 2026-11-24. MS Linear is an independent brand; model numbers are used for compatibility identification only. Dimensions are for catalogue comparison; confirm the drawing before ordering.