Maintenance

Guideway lubrication: interval, amount and failure signs

A guideway that is sized correctly still fails early if the raceway runs dry. The service interval is written in kilometres on most datasheets, which is useless on a machine that runs in metres per minute. This page converts it, and covers what to put in and what a dry block looks like.

100 km rule Grease ≤60 m/min 6 min read

01What the grease is actually doing

Three jobs, and only the first is obvious:

  • Separating the rolling elements from the raceway. A film a few micrometres thick keeps metal off metal. Once it breaks down, the balls or rollers polish the raceway and the block starts to rattle.
  • Sealing the block from contamination. Grease fills the gap behind the wiper, so dust that gets past the seal meets a barrier instead of the raceway.
  • Carrying heat away from the contact. Small effect at low speed, significant on a fast axis where the block runs warm.

Grease also acts as a wear indicator. When a block is opened for service, the colour and texture of the old grease tell you more about the axis than any gauge: black and gritty means contamination is getting past the wipers, brown and hard means it has been running hot.

02Grease or oil: the 60 m/min line

Grease is the default. It stays in the block, needs no piping and survives intermittent duty. Above roughly 60 m/min the grease film is thrown off the raceway faster than it can be replenished, and oil becomes the better answer.

LubricantSpeed rangePractical notes
Lithium grease NLGI 2 typicalUp to 60 m/minFactory fill on most blocks. Simple, but the interval has to be respected.
Oil 30–150 cStAbove 60 m/minNeeds continuous supply, roughly 0.3 cm³ per hour per block, and a return path.
Self-lubricating block reservoirUp to 60 m/minReservoir inside the block extends the interval; still needs periodic inspection.

Oil is not simply "better at speed". It is a system: pump, tubing, metering and a way to keep the oil off the workpiece. On a machine where coolant already floods the rail, oil lubrication is usually the wrong choice for that reason alone.

03The 100 km rule, converted to hours

The nominal service interval is every 100 km of travel. Convert it with the average speed the axis actually runs, not the maximum:

Interval T (hours) = 100,000 / (Ve × 60)
Ve average speed in m/min over a full cycle

At 30 m/min average, the interval is 100,000 / 1,800 = about 56 running hours. On a two-shift machine that is roughly every three and a half working days, which is why maintenance schedules written in "once a month" fail.

Average speedRelubrication intervalTwo-shift days
5 m/minAbout 333 hAbout 21 days
10 m/minAbout 167 hAbout 10 days
20 m/minAbout 83 hAbout 5 days
30 m/minAbout 56 hAbout 3.5 days
45 m/minAbout 37 hAbout 2.3 days
60 m/minAbout 28 hAbout 1.7 days

Average, not peak. A machine that rapids at 60 m/min but spends most of its cycle cutting at 5 m/min should be scheduled on the average. Using the peak over-greases the block and pushes seals out; using neither leaves the raceway dry.

04How much grease, and how to apply it

The quantity comes from the block datasheet, not from a rule of thumb: each block has a fill volume that covers the raceway and the recirculation path. The procedure matters as much as the amount:

1

Wipe the rail and the wiper

Old grease carries the contamination that was stopped at the seal. Pushing it back into the block during service is the most common way a bearing is destroyed by its own maintenance.

2

Apply at the raceway inlet

Grease goes where the rolling elements will pick it up, not on the outside of the block. Use the grease nipple or the inlet port if the block has one.

3

Run the full stroke

Three to five full passes distribute the grease along the raceway and through the recirculation path. A block that is only moved a few millimetres after service has grease at one end.

4

Wipe the excess

Grease pushed out at the ends attracts chips. What stays on the rail is a contamination trap, not a reserve.

Self-lubricating blocks change the schedule, not the principle: the reservoir extends the interval, but the wiper still has to be inspected and the rail still has to be clean. The E2 self-lubricating series and the EL series are the usual choice for lines where access for service is difficult.

05Dry and over-greased look different

ConditionSymptomsWhat to do
Dry racewayFaint squeal at low speed, then a rattle; friction rises and the drive current climbs; old grease is dark and hard.Clean, refill, shorten the interval. Check the wiper for a gap that is letting contamination in.
Over-greasedBlock runs warm, grease pushed out past the seals, slight chattering as the block works against its own fill.Remove excess, extend the interval, check that the correct fill volume was used.
ContaminatedGritty grey grease, scoring along the raceway, uneven wear on one side of the block.Replace the wiper and the grease; add a metal scraper or a bellows cover if the environment justifies it.

Temperature is the quickest field check. A block that runs noticeably hotter than its neighbour on the same axis is either dry, over-preloaded or misaligned. All three show up as heat before they show up as accuracy loss.

06When the interval should be halved

  • Dust or chips in the air. Contamination consumes grease and abrades the wiper. Halve the interval and review the sealing; dust protection covers which configuration fits which environment.
  • Coolant mist or washdown. Water emulsifies grease; the block needs a water-resistant fill and a shorter cycle.
  • Vertical or wall-mounted axes. Gravity drains the upper raceway.
  • Heavy preload or high load. The film is thinner and breaks down sooner.
  • Ambient above 40 °C. Grease oxidises faster and the base oil separates.

Halving is a starting point, not a rule. Machines in foundry or woodworking environments often end up at a quarter of the nominal interval, and the only way to find that out is to inspect a block after a month of production rather than after a failure.

07Questions we get

Is the 100 km relubrication interval a hard limit?

It is a nominal service interval for a clean, normally loaded axis on lithium grease. Dust, coolant, heat, vertical mounting and heavy preload shorten it; halving is the usual field practice.

Can I use any lithium grease?

Use the grade the block was filled with, or one the supplier confirms as compatible. Mixing different thickener bases can soften the fill and let it migrate out.

Do sealed blocks still need relubrication?

They hold the fill longer but are not sealed for life. The seals slow grease loss and keep contamination out; the raceway still consumes the film.

Why does a vertical axis need a shorter interval?

Gravity drains grease from the upper raceway, so the film thins faster at the top of the stroke. Vertical and wall-mounted axes are usually serviced at about half the horizontal interval.

08Where to go next

If the block is running hot, the cause may be preload or alignment rather than grease: the accuracy and preload guide covers both. Drive force and seal drag are quantified in friction and drive force. An inverted or wall-mounted block loses its grease film sooner, which is covered in mounting orientation, and a dry raceway usually announces itself as noise before it shows up as wear. For a first-pass duty estimate, the size calculator returns the load per block, and the selection guide covers rail length and joint policy.

Blocks with a grease reservoir: E2 series, EL series. For heavy or contaminated lines, the HG series with a reinforced wiper is the usual starting point.

Part of the MS Linear product selection library — the engineering notes behind our linear guideways, ball screws, modules, shafts and bearings. For the full range, browse the MS Linear catalogue or the selection library index.

This page covers the essentials. For the complete selection PDF, full part-number tables and a matched recommendation, contact MS Linear or email [email protected] — we will send the relevant selection PDF for your load case.

China Factory Direct · Drop-in Compatible Dimensions

Buying Precision Motion Components from China
is Your Best Choice!

Factory-direct quality and worldwide shipping — standard parts leave the factory in 3–10 days, custom strokes and leads in 15–20 days (2–3 weeks). Send your drawing or the original part number and get a quotation within 24 hours.

Drop-in Replacement Factory-Direct Price Global Shipping OEM / Non-Standard Bulk Discounts