01What the block integrates
- Fixed-end bearing pair with lock nut and seal, already installed in the housing.
- Motor pilot bore machined from the same datum as the screw bore, so the coupling has no offset to absorb.
- Nut bracket interface on the moving side, or a separate bracket when the nut has to float.
The catalogue describes the result directly: the carriage assembly is installed without adding a fixed side, the motor is located by the embedding section, and the screw side and motor side are one piece, which suppresses the axis deviation between them. That is a manufacturing statement, not a marketing one: the alignment that used to depend on the assembly now depends on the block.
02The two families on the moving side
| Part | Behaviour | When it belongs |
|---|---|---|
| HM integrated block | Support, housing and motor pilot in one casting | Compact axes, servo and stepper drives, where the motor is chosen with the axis |
| MGD nut block | Fixed-position nut bracket, bolted to the carriage | Standard build with a separate support seat |
| MC nut block | Adjustable nut bracket | Where the nut must be aligned to the rail after assembly |
The HM range runs from HM12 to HM30 in the catalogue, with variants keyed to the motor flange — HM12-57 and HM12-60 are two different flange sizes on the same 12 mm class block. Read the suffix before comparing prices: the block, not the screw, is what changes.
03Sizing: screw first, then motor flange
2 Servo or stepper frame size → the flange suffix
3 Motor shaft diameter and length → the coupling and the pilot depth
4 Stroke and critical speed → whether the block can carry the screw at all
The block class follows the screw, not the load: a 12 mm screw in a 20 class block is a mismatch of bore and bearing. The flange suffix follows the motor, and the two are independent, which is why the code carries both.
04The trade: stiffness against flexibility
An integrated block is stiffer and more accurate, and it removes two joints that used to absorb tolerance. That cuts both ways:
| Property | Integrated block | Separate parts |
|---|---|---|
| Axial runout | Set by one machining datum | Set by the assembly, varies with the fitter |
| Assembly time | Low; no shimming of the motor | Higher; coupling alignment needed |
| Change a motor | New block or machined adapter | New bracket only |
| Thermal growth | Must be absorbed elsewhere | Can be taken at the bracket joint |
A long screw grows with heat. If both ends are fixed in one rigid line, that growth has to go somewhere: into the bearing preload, the coupling, or the nut. On a long axis, prefer one fixed end and let the other end float, even when the fixed end is an integrated block.
05Installation order
- Mount the block on the machined face first; it is the datum for everything after.
- Insert the screw and set the lock nut at the specified torque.
- Fit the coupling with the motor shaft free, then bring the motor into the pilot bore.
- Check axial play at the nut, not at the motor.
- Run the axis at low speed and listen for a once-per-turn sound, which is misalignment, not preload.
06Questions we get
What does an integrated block actually remove?
The joint between the fixed-end support and the motor bracket. In a conventional build that joint's alignment error becomes axial runout; in an integrated block both sides share one datum.
When is a separate nut bracket better?
When the nut has to float, when thermal growth must be taken up at a joint, or when the motor may change later. MGD is fixed position, MC is adjustable.
Does the block fix the motor centre height permanently?
Yes. The block is machined for a specific motor flange and screw diameter, so a later motor change may mean a new block. Confirm the flange drawing before ordering.
07Where to go next
All guides are listed on the knowledge index and grouped on the knowledge hub. The screw code is decoded on ball screw part numbers; the fixed end on support seats; the axis on module selection.
Products: ball screw category. Send the screw diameter, the motor flange drawing and the stroke, and we will confirm the block class and the flange suffix.
Part of the MS Linear product selection library — the engineering notes behind our linear guideways, ball screws, modules, shafts and bearings. For the full range, browse the MS Linear catalogue or the selection library index.
This page covers the essentials. For the complete selection PDF, full part-number tables and a matched recommendation, contact MS Linear or email [email protected] — we will send the relevant selection PDF for your load case.